The Growing Demand for Lift Stations

As cities and communities continue to expand, the need for efficient wastewater management systems has never been greater. One critical component of this infrastructure boom is the lift station. A sewer lift station system is designed to move wastewater from lower to higher elevations when gravity flow alone isn’t enough. The growing demand for lift […]
Preventative Maintenance Checklist for Submersible Pumps

Proactive maintenance is key to extending the life of submersible pumps and ensuring they operate at peak efficiency. A structured preventative maintenance program helps catch issues early, preventing costly unplanned downtime. The following checklist outlines routine inspection tasks, best practices, and recommended intervals for maintaining submersible pumps in industrial, commercial, and municipal applications. Maintenance frequency […]
How to Size a Submersible Sewage Pump for Maximum Efficiency

When it comes to sewage lift stations, selecting the right submersible pump is one of the most important decisions you’ll make. Oversize the pump, and you risk short-cycling, wasted energy, and excessive wear. Undersize it, and you’ll face backups, downtime, and unhappy customers. The key is finding the sweet spot—a pump that’s properly sized for […]
Effects of Grease Buildup in Sewer Pump Stations

Impact on Flow and Pumping Efficiency When fats, oils, and grease (FOG) enter a wet well, they adhere to walls and form thick, solid caps. Just a ½ inch layer of grease in an 8-inch pipe can reduce flow capacity by 25 percent, driving up pump run times and energy costs proportionally. Grease accumulation is […]
Pump Kits from Triple D Pump: Everything You Need in One Package

When it comes to pump installation or replacement, having all the right parts on hand is critical. Missing even one piece can delay a project, add unnecessary costs, and create frustration for both contractors and facility managers. That’s why Triple D Pump offers complete pump kits—convenient, all-in-one solutions designed to make installation easy, efficient, and […]
Temporary Lift Stations: What They Are and Where They Can Be Used

Sometimes, wastewater doesn’t wait for construction schedules, repairs, or system upgrades to be finished. That’s where temporary lift stations step in—providing reliable pumping solutions exactly when and where they’re needed. Whether for short-term projects or emergency situations, a temporary lift station can keep things flowing smoothly until a permanent system is back in place. What […]
Understanding Total Dynamic Head (TDH) in Sewer Lift Stations—and How to Calculate It

When it comes to designing or troubleshooting a sewer lift station, one term you’ll hear a lot is Total Dynamic Head (TDH). It’s not just industry jargon—TDH is the key measurement that ensures your pumps are sized correctly and your system runs efficiently. If you get it wrong, you could end up with poor performance, […]
Understanding Freeze Lines and Their Impact on Sewer Lift Stations

When designing or installing a sewer lift station, one often-overlooked factor is the freeze line—the depth at which the ground freezes during cold weather. While it might not seem like a big deal, the freeze line can vary significantly from place to place, and it plays an important role in protecting your system from costly […]
What You Need to Know for a Free Sewer Lift Station or Pump Quote

At Triple D Pump Company, we pride ourselves on making the quoting process as easy—and accurate—as possible. Whether you’re planning a brand-new sewer lift station or replacing an existing pump, the more details you can share up front, the better we can design a solution that meets your needs. Here’s a quick guide on the […]
Different Kinds of Control Panels for Pump Stations

Different Kinds of Control Panels for Pump Stations Pump station control panels vary widely to meet specific application requirements, from simple single-pump setups to complex, multi-pump municipal installations. Types by Pump Count Simplex panels Control a single pump Often direct-on-line (DOL) starting for small loads Duplex panels Manage two pumps with alternation logic Ensures even […]